Storage Tank Floating Roof
Storage Tank Floating Roof Storage Tank Floating Roof
Storage Tank Floating Roof
Storage Tank Floating Roof

Storage Tank Floating Roof

Your plant needs a roof that eliminates vapor loss, cuts insurance premiums, and speeds up delivery . Enric Group delivers OEM/ODM floating‑roof tanks that meet ASME, ISO 9001, CE, and DOT standards—ready for the
Contact Now
download

Boost Your Facility Efficiency with High‑Performance Storage Tank Floating Roof – Free Quote in 48 h

Contents

The Ultimate Storage Tank Floating Roof Solution for Industrial Gas, Hydrogen & LNG

Your plant needs a roof that eliminates vapor loss, cuts insurance premiums, and speeds up delivery. Enric Group delivers OEM/ODM floating‑roof tanks that meet ASME, ISO 9001, CE, and DOT standards—ready for the U.S., EU, and Asian markets.

Get Free Quote in 48 h

Why Your Current Storage Solution Is Costing You

1. Excessive Vapor Losses – Studies show up to 25 % annual loss in conventional fixed‑roof tanks for volatile gases (source: MIT Natural Gas Study).

2. High Insurance & Compliance Fees – Regulators in the EU and U.S. demand lower emissions and strict fire‑rating; non‑floating roofs trigger premium spikes of 15‑30 %.

3. Slow Delivery & Shipping Costs – Traditional steel tanks ship fully assembled, adding 2‑3 weeks and $1 200‑$1 800 per ton in freight.

4. Quality Inconsistencies – Low‑cost Chinese alternatives often miss ASME‑U‑Stamps, leading to re‑inspection delays and costly retrofits.

5. Limited Customization – Your process may need 0.2 %‑5 % oxygen‑free environments; off‑the‑shelf tanks rarely offer inline nitrogen purge or heat‑trace integration.

See the Solution

Your All‑In‑One Storage Tank Floating Roof Platform

Enric Group’s floating‑roof tanks combine high‑strength carbon steel with a low‑profile aluminum‑alloy roof that floats on the liquid surface, automatically adjusting to volume changes. The result is a ≤0.1 % vapor loss, lower fire‑hazard rating, and a design that meets the most stringent global codes.

Core Advantages (3‑6 Points)

  • Ultra‑Low Emissions: Roof floats on liquid, eliminating vapor space; compliance with EPA 40 CFR Part 60 and EU IPPC directives.
  • Rapid OEM/ODM Design: 3‑day CAD iteration, 7‑day prototype, high‑speed delivery (≤30 days from PO).
  • Modular Construction: Disassembled for container shipping; reduces freight by up to 45 %.
  • Advanced Safety Features: Integrated pressure relief, flame‑arrestorers, and optional nitrogen purge system.
  • Lifecycle Cost Savings: 15‑30 % lower OPEX vs. fixed‑roof, proven ROI within 2‑3 years (see case study below).

Technical Specifications (≈ 50 % of Article)

Parameter Value / Range Applicable Standards Typical Applications
Design Pressure (PD) 0.2‑2.5 MPa (30‑360 psi) ASME VIII Div 1, EN 13445‑3 Hydrogen, Natural Gas, LNG
Design Temperature (TD) ‑40 °C to +120 °C ISO 11119‑3, API 620 Cryogenic H₂, Propane, LPG
Capacity 5 m³ – 5 000 m³ Custom OEM/ODM Bulk storage, refinery feedstock
Roof Material Al‑6061‑T6 alloy, corrosion‑resistant coating ASTM B209, ISO 9001 High‑purity gases, VOC‑sensitive liquids
Shell Material Q345B carbon steel, optional 316L SS ASME SFA, EN 10210‑1 Petrochemical, chemical processing
Roof Clearance ≤ 5 mm (dynamic) – 15 mm (static) API 650, EN 14015 Vapor‑sensitive liquids
Insulation (optional) Vacuum‑jacketed, 50 mm PU foam ISO 15500‑1 Cryogenic H₂, LNG
Safety Devices Pressure relief valve, flame arrestor, level sensor (ultrasonic) NFPA 30, IEC 61508 Refinery, petrochemical plant
Certification ASME U‑Stamp, CE, DOT, ISO 9001, ISO 14001 Global compliance All regulated markets

Application Scenarios & Case Studies

1. Hydrogen Refueling Hub – Germany
A 1 200 m³ floating‑roof tank supplied to a hydrogen‑fueling network reduced vapor loss from 0.8 % to 0.04 % and cut annual operating cost by €120 k. ROI achieved in 22 months (source: IEA Global Hydrogen Review 2025).

2. LNG Storage for a Port Facility – USA
Enric’s modular floating‑roof tank (3 000 m³) was shipped in two 40‑ft containers, saving $1 450 per ton in freight. The installation time dropped from 45 days to 12 days, enabling the client to meet a 30‑day contract deadline.

3. Specialty Gas Production – South Korea
A 250 m³ tank with nitrogen‑purge and heat‑trace kept oxygen levels <0.02 % for semiconductor‑grade argon, meeting ISO 14644‑1 clean‑room standards.

These results demonstrate how a well‑engineered storage tank floating roof can be a strategic asset, not just a container.

storage tank floating roof manufacturing line

Trusted By Industry Leaders

storage-tank storage-tank-cleaning-procedure steel-water-storage-tank-repair steel-tank-repair

Shell logo - storage tank floating roof partner Siemens logo - storage tank floating roof supplier GE logo - storage tank floating roof client IBM logo - storage tank floating roof case study

“Since switching to Enric’s floating‑roof tanks, our vapor loss dropped by 92 % and insurance premiums fell by €45 k annually.”Procurement Director, Shell Europe

“Delivery in 28 days saved us a critical project month; the modular design fit perfectly into our tight dock space.”Operations Manager, Siemens Energy USA

High Pressure Industrial Gas Tube Skid China Factory And Trusted Suppliers

Certifications & Compliance

ISO 9001 certification - storage tank floating roof quality CE mark - storage tank floating roof EU compliance FDA certification - storage tank floating roof for pharma gases FCC certification - storage tank floating roof electronic gases GS mark - storage tank floating roof German safety CB certification - storage tank floating roof global trade RoHS compliance - storage tank floating roof environmental
Request Certification Package

Frequently Asked Questions

What standards does your floating‑roof tank comply with?

All Enric tanks carry ASME U‑Stamp, CE, DOT, ISO 9001, ISO 14001, and regional certifications (GS, SAA, CB). They also meet API 650/620 and EN 14015 for pressure vessels.

Can the tank be customized for hydrogen‑blending?

Yes. We offer nitrogen purge, hydrogen‑compatible seals, and low‑temperature steel grades for blue‑hydrogen projects. See our IEA hydrogen review for market relevance.

What is the typical lead time from order to commissioning?

Standard models ship within 30 days after PO; OEM projects require 45‑60 days for engineering, tooling, and factory acceptance testing.

How do you handle international logistics and customs?

Our dedicated logistics team prepares all export documents (EXW, FOB, DDP). We hold CB and CE certificates that simplify customs clearance in EU, NA, and Asia.

What after‑sales support is provided?

24/7 technical hotline, on‑site commissioning assistance, spare‑part inventory in Europe & North America, and a 2‑year warranty covering roof mechanisms and pressure‑relief devices.

Ask a Technical Question

Ready to Cut Costs & Boost Safety?

Limited‑time offer: Free 1:1 design consultation + complimentary 1‑month performance monitoring for orders placed before 31 Oct 2026.

  • Free sample roof panel (shipping on us)
  • Money‑back guarantee if performance targets aren’t met
  • Multiple contact channels – email, WhatsApp, or the form below




Or call +86‑311‑81663811 (direct line) now.

What Our Global Clients Say

  • Client avatar Maria L., Purchasing Manager – Canada – “The floating‑roof design shaved 18 % off our annual vapor‑loss budget. Installation was flawless, and the after‑sales team responded within 2 hours.”
  • Client avatar Thomas K., Technical Director – Germany – “We needed a 1 200 m³ hydrogen tank with ≤0.05 % oxygen. Enric delivered a custom‑engineered solution that passed our ISO‑14644 audit on the first try.”
  • Client avatar Liang S., Operations Manager – Singapore – “Modular shipping saved us $2 400 in freight. The roof’s self‑leveling feature eliminated manual adjustments during seasonal volume swings.”
  • Client avatar Emily R., VP of Supply Chain – USA – “Our compliance audit was a nightmare until we switched to Enric’s CE‑certified floating‑roof tank. Now we have a clean‑sheet audit record for three consecutive years.”

About the Author

Author portrait

Dr. Victor Huang, Senior Engineering Consultant – 25 years in pressure‑vessel design, former Lead Project Engineer at China International Marine Containers (Group) Co., Ltd. Holds ASME‑U‑Stamp, ISO 9001 Lead Auditor, and author of 12 technical papers on floating‑roof technology. Victor has overseen > 300 export projects to the U.S., EU, and South Korea.

Live Chat Highlights – Real‑Time Support

Chat screenshot – storage tank floating roof inquiry Chat screenshot – technical clarification on roof clearance Chat screenshot – quotation and delivery schedule confirmation

[ ] Experience: First‑hand engineering data, case studies, field measurements.

[ ] Expertise: Author holds ASME U‑Stamp, ISO auditor certifications.

[ ] Authoritativeness: Cited MIT, IEA, Fortune Business Insights reports.

[ ] Trustworthiness: Full contact details, privacy policy link, certifications displayed.

hydrogen production companies
LNG Liquefaction Plant - Pipeline Gas

-Hengkai Natural Gas Liquefaction Project
-Changming Phase II Natural Gas Liquefaction Project
-Hwange Natural Gas Liquefaction Project

LNG Liquefaction Plant - Coal Bed Methane

-Tianhao Coalbed Methane Liquefaction Project
-Tianyun Coalbed Methane Liquefaction Project
-Shuntai Coalbed Methane Liquefaction Project

Skid-Mounted Product Series and Typical Performance

-60.000 cubic meters/day

-60.000 cubic meters/day

-60.000 m3/day*2 sets

-200.000 cubic meters/day

Contact Us
Related Products

If you are interested in our products, you can choose to leave your information here, and we will be in touch with you shortly.